GrayWolf DirectSense IAQ
Manufacturer GrayWolf Sensing Solutions
Lowest Price: $2,995.00
Average Rating:
  total 2 Reviews   Write Reviews
   

DirectSense IAQ Monitors from GrayWolf make proactive indoor air quality surveys efficient and easy to conduct. Optimize the balance between facility energy efficiency and occupant health & comfort. Identify potential IAQ issues before they become problems and respond immediately to complaints with the highly accurate, extremely advanced and the most intuitive portable IAQ test instrumentation available today.

This IAQ meter is designed for both walk-thru surveys and for long term (hours/days/weeks) trend logging: the 2 modes necessary for thorough Indoor Air Quality investigations.

Excellent documentation is essential for IAQ surveys. GrayWolf utilizes mobile PCs to let you document your walk-thru in great detail. And generate professional, information-rich IAQ reports at the push of a button.

GrayWolf IAQ kits harness the power of mobile PCs to significantly improve your IAQ test capability. Connect to Mobile Windows™ Pocket PCs, to laptop, notebook or ultra-mini XP PCs. GrayWolf DirectSense kits are typically supplied with an HP iPaq Pocket PC included.

Features

Multi-function

  • Simultaneous measurement of up to five (5) key IAQ indicators; VOCs, CO2 (dilution ventilation), CO, %RH, °C/°F in one probe
  • Add an additional toxic gas sensor to the probe, from a choice of 20+ specific gases
  • With an added probe, simultaneously measure up to six (6) other gases
  • Optional telescoping hotwire airspeed probes, particulate concentration module, particle count module, differential pressure module

Data Logging

  • Manual "snapshot" or automatic "trend" datalogging available
  • Store enhanced survey information on-site; data and text, drawings, audio notes, photos and more...

Reporting

  • Allows logged data to be down-loaded to WolfSense PC software for analysis
  • Optional "Advanced Report Generator: IAQ Edition" software makes comprehensive IAQ report generation easy and efficient

Intuitive menu system

  • Minimum training required; if you know Windows, you know how to navigate WolfSense
  • Easy to use
  • Screen prompts user through operation
  • Easily customize/optimize the user interface for your specific application

Special user features

  • On-board "hand-holding", help files
  • IAQ educational materials, IAQ & sensor tips, government & industry guidelines, health effects, typical background levels and more…
  • Add your own IAQ related procedures, documents and Word field forms for on-site use

Large and clear display

  • Measures numerous variables simultaneously, as many as you want at one time
  • Back-lit display ensures readings are always visible
  • Automatically updated when probes are plugged in
  • On-screen help files for easy operation

Pouches, Case

  • Probe pouch keeps sensors away from the influence of operators breath
  • Mobile PC pouch for true hands-free operation
  • Rugged hardshell case for secure trend logging and for protection during transport

Probe connectors

  • Two probes may be fitted at one time, plus a 3rd party instrument
  • Order optional Bluetooth wireless for cable-free connection

Standard DirectSense IAQ Kits:

DirectSense IAQ PPC

DirectSense IAQ PPC Plus

DirectSense IAQ PPC Pro Plus

HP iPaq Windows Mobile Pocket PC* w/GrayWolf probe adapter

HP iPaq Windows Mobile Pocket PC* w/GrayWolf probe adapter

HP iPaq Windows Mobile Pocket PC* w/GrayWolf probe adapter

IQ-410 Four Function probe

CO2, CO, %RH, ◦C/◦F

IQ-610 Five Function probe  VOCs, CO2, CO, %RH, ◦C/◦F  (+1 EC gas sensor slot)

IQ-610 Five Function probe  VOCs, CO2, CO, %RH, ◦C/◦F  (+1 EC gas sensor slot)

AS-201 telescoping Hotwire Airspeed  probe

Hardshell security case, probe pouch and mobile PC pouch

Hardshell security case, probe pouch and mobile PC pouch

Hardshell security case, probe pouches and mobile PC pouch

1 year software subscription

1 year software subscription

3 year software subscription

WolfSense PC data analysis software

WolfSense PC data analysis software

WolfSense PC data analysis software

WolfSense ARG Advanced Report Generator software

*Kits including notebook or tablet PCs, or set up to use with your own Pocket PC or Laptop are also available




Click to enlarge
   
Sort By:    
Company Name Average Company Rating Price Click to Buy
Read & Write Store Reviews $2,995.00
   
 Product Reviews
 Write Reviews Sort By:
  Decent but fragile 2006-10-27
Reviewed By: [footserelli5]
Was this review helpful to you?
 
Nice functions and great array of sample parameters. Easy datalogging
and software package for graphing. I admit I don't get full use out of
programming the PDA for locations, etc. but the option is there. Downside:
I've found the interface at the PDA and the probe cable to become easily
damaged and disloged with use. We've replaced the plug twice in two
years. Also requires factory calibration, no field calibration package. I
understand they're coming out with a "tougher" unit, I look forward to it,
because the sensors in general are solid.

 
 
  Snazzy Equipment 2006-10-19
4 of 4 (100%) people found the following review helpful.
Reviewed By: [IAQman]
Was this review helpful to you?
 
I really like the DirectSense IAQ monitor compared to my aging TSI
equipment. Both companies offer top notch equipment and you can't go
wrong with either.

I like the fact that the GrayWolf uses a pocket PC. Leave the computer
interface to Microsoft, not to a equipment manufacturer. GrayWolf's
software allows you to convert temperature and RH to dewpoint and
humidity ratio (grains of moisture per pound of dry air). It also has great
data logging functions.

I would strongly suggest that anyone out there who purchases a GrayWolf
read through the user guides. I know there are several features that I'm
not using. In fact, often times I just take the reading and write it down on
a piece of paper as opposed to recording it in the software.
 
 